HERE IS WHAT YOU GET:
2.5 Ton Comfort™ 15 SEER2 AC 26SCA530 FJ5ANXB36L

 

Save an additional10%, use coupon code save10!
*Important note regarding this item:
Limited Availability Call or email for Stock Status 1-866-598-7281
Free Shipping in the Continental US!

26SCA5 installed with FT5 or FJ5 Air Handlers 

This unit has been designed utilizing Carrier’s non-ozone depleting and low global warming potential Puron Advance™ refrigerant. Heat pumps with Puron Advance™ refrigerant provide a collection of features unmatched by any other family of equipment.

Features / Benefits
Efficiency
14.3 - 16.0 SEER2 / 10.0 - 12.5 EER2 / 7.5 - 7.8 HSPF2 (depending on unit size and indoor combination installed)
Microtube technology refrigeration system
Indoor air quality accessories available

Comfort
System supports programmable or standard thermostat controls
Sound
Sound levels as low as 70 dBA

Reliability
Non-ozone depleting and low global warming potential Puron Advance™ refrigerant
Scroll compressor
Internal pressure relief valve
Internal thermal overload
Loss of charge switch
Filter drier
Balanced refrigeration system for maximum reliability

Durability
WeatherArmor™ Ultra Protection Package:
Solid, durable sheet metal construction
Dense wire coil guard

Applications
Long-line - up to 250 feet (76.20 m) total equivalent length, up to 200 feet (60.96 m) condenser above evaporator, or up to 80 ft. (24.38 m) evaporator above condenser (See Longline Guide for more information.)
Low ambient cooling (down to 0°F/-17.8°C) with approved low ambient accessory kits
Limited Warranty
5-year parts limited warranty (including compressor and coil) 10-year parts limited warranty (including compressor and coil) with timely registration*
– Equipment must be registered within 90 days of original installation, except in jurisdictions where warranty benefits cannot be conditioned on registration.
* Applies to original purchaser/homeowner and not available to subsequent owners except in jurisdictions where applicable laws dictate otherwise.

See warranty certificate for complete details and restrictions.
Prop 65 
Warning: this product contains a chemical known to the State of California to cause cancer. P65Warnings.ca.gov

Description- FT5 Performance Puron Advance VS Air Handler R454B Refrigerant 


FT5 PERFORMACE PREMIUM ENVIRONMENTALLY RESPONSIBLE FAN COIL

This is the premium air handler combining the proven technology of Carrier fan coils with environmentally balanced Puron Advance® refrigerant.Carrier is proud to introduce its InteliSense™ technology 
which is a connected system solution when paired with Internet-connected Ecobee for Carrier smart thermostats to deliver a smarter, faster, and more efficient service experience to the homeowner, while also providing them peace of mind. The FT5 achieves an operational advantage when the variable speed ECM (Electronically Commutated Motor) is combined with a Carrier Performance™heat pump or air conditioner with Puron Advance® refrigerant.
With attention to quiet, efficient, and comfortable operation, Carrier have has developed a new benchmark for superior indoor comfort and control. Carrier’s heat pump and air conditioning systems feature Puron Advance® refrigerant (R-454B), the chlorine-free refrigerant that is the future for the residential heating and cooling industry. 

The FT5 using Puron Advance® refrigerant maximizes performance for environmentally balanced systems. In addition to environmental safety, these systems are 30 to 40% more efficient than standard heating and cooling systems, thereby combining excellence in efficiency and environmental responsibility.
The FT5 provides these benefits due to Carrier’s command of ECM technology. These motors are extremely efficient at all speeds, and enable the FT5 to operate at the correct speed to deliver airflow precisely, ensuring proper performance across a wide range of duct static pressures. This adaptive efficiency also makes installation quality easier to achieve for today’s demanding homeowner. Carrier’s command of ECM technology may be most evident in the comfort advantages that ECM can deliver. Operation set up steps on the InteliSense™ Board provide the installing technician with alternatives to maximize comfort and efficiency. For true indoor comfort, the homeowner can achieve command of both temperature and humidity in cooling and heating modes.
Another feature which sets the FT5 apart is the factory-installed TXV, which enhances efficiency and provides compressor protecting operation at all recommended conditions. Grooved tubing, louvered aluminum fins, and the large face areas of the FT5 refrigerant coils also provide superior efficiency, for high SEER and HSPF performance. 

Carrier leads the way in condensate control, a hallmark of these multipoise fan coils.
All of these featured components are protected within a rugged, pre-painted metal cabinet lined with super thick, high density insulation. For neat, high quality installations the unit exterior features sweat refrigerant connections for simple leak free performance, and multiple electrical entry for both high and low voltage service.
Assembled at the factory compliant with low leak requirements of less than 2% cabinet leakage rate at 1 inches W.C. and 1.4% cabinet leakage rate at 0.5 inches W.C. when tested in accordance with ASHRAE 193 standard.

FEATURES
Environmentally Balanced Refrigerant Technology
• Puron Advance®, chlorine-free, non-ozone depleting refrigerant
• Refrigerant leak detection dissipation system for added safety
• Thermostatic Expansion Valve (TXV) designed to maximize
performance with Puron Advance® refrigerant
Energy Efficient Operation
• Variable Speed Constant Airflow ECM (Electronically Commutating
Motor) operates efficiently at all speeds
• Maximizes efficiency of heating and cooling systems
• Ultra low power consumption during fan only operation
Indoor Weather Control
• Warm, comfortable heating air temperatures
• Unmatched humidity control, especially with Carrier’s thermostat
with relative humidity controls
Airflow and Sound Technology
• Diffuser air discharge section for high airflow efficiency and quiet,
smooth operation
• High duct static capability
• Design meets stringent regulations for cabinet air leakage of less than 2% cabinet leakage rate at 1 inches W.C. and 1.4% cabinet leakage rate at 0.5 inches W.C. when tested in accordance with ASHRAE 193 standard.
Condensate Control and Disposal Technology
• Minimal standing waterless microbial growth for improved IAQ and reduced condensate line clogging and related condensate leakage 
• Condensate fittings relocated away from turbulent airflow patterns at the blower entrance for improved condensate control performance
• Overflow feature for slope coil units allows condensate to exit the unit without damage to product under clogged primary and secondary line conditions.
• Tested for condensate disposal at conditions much more severe than those required by AHRI
• Primary and secondary drain connections to comply with HUD
• All pans constructed of an injection molded glass-filled polycarbonate engineered resin material, with brass drain connections.
• High density, super thick cabinetry insulation with vapor barrier
• Pre-painted galvanized sheet metal cabinet
Heat Transfer Technology
• Grooved tubing
• Lanced sine wave aluminum fins
• Discreet refined counter-flow refrigerant circuitry
• Bi-flow hard shut-off TXV metering device with mechanical fittings Quality Assisting, Ease of Installation and Service
Features
• All units multipoise
• Provision made for suspending from roof or ceiling joints
• Modular cabinet on 36 thru 60 size units
• Sweat connections for leak free service
• Multiple electrical entry for application flexibility (high and low voltage)
• Low voltage terminal strip, to safely hold connections within the cabinet
• Cabinet construction features innovations designed to prevent cabinet sweating
Controls and Electrical Features
• InteliSense™ Board to maximize comfort, efficiency, and safe heater airflow operation
• Easy plug connection provided for quick installation of accessory heater packages
• 40VA 208/230V transformer
• Replaceable 5A blade-type auto fuse protects against transformer secondary short Filter Features 
• Factory supplied filter
• New standard sized filter rack fits most common size replacement filters
WARRANTY
• Default 5-year parts limited warranty (including compressor and coil)
– 10-year parts limited warranty with timely registration *.
Equipment must be registered within 90 days of original installation, except in jurisdictions where warranty benefits cannot be conditioned on registration.
* Applies to original purchaser/homeowner and not available to subsequent owners, except in jurisdictions where laws dictate otherwise.
See Warranty certificate for complete details and restrictions

Safety Considerations

Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause death, personal injury or property damage. Consult a qualified installer, service agency, or your distributor or branch for information or assistance. The qualified installer or agency must use factory-authorized kits or accessories when modifying this product.
Refer to the individual instructions packaged with kits or accessories when installing.
Follow all safety codes. Wear safety glasses, protective clothing and work gloves. Have a fire extinguisher available. Read these instructions thoroughly and follow all warnings or cautions included in literature and
attached to the unit. Consult local building codes and the current editions of the National Electrical Code (NEC) NFPA 70.

Recognize safety information in instruction manuals, be alert to the potential for personal injury.
Understand the signal words DANGER, WARNING, and CAUTION.
These words are used with the safety-alert symbol.

DANGER identifies the most serious hazards which will result in severe personal injury or death.

WARNING signifies hazards which could result in personal injury or death. 

CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage.

NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.

! WARNING PROPERTY OR PERSONAL INJURY HAZARD
Risk of fire. Flammable refrigerant used.
To be repaired only by trained service personnel. 
Do not puncture refrigerant tubing.
Auxiliary devices which may be ignition sources shall not be installed in the ductwork, other than auxiliary devices listed for use with the specific appliance. 

See instructions.
Dispose of refrigerant properly in accordance with federal or local regulations.
Failure to follow proper R-454B mitigation system installation instructions can result in property damage, personal injury, or death. 
If any fault codes are listed, please troubleshoot to prevent system malfunction.

FJ5 AIR HANDLER TECHNOLOGY AT ITS FINEST

The FJ5 fan coil has the proven technology of Carrier fan coil units with Puron Advance refrigerant as well as vertical and horizontal applications. The design features contoured condensate pans with rugged drain connections, ensuring that little water is left in the unit at the end of the cooling duty cycle. The lack of standing condensate and corrosion free pans improves IAQ and product life, features homeowners appreciate.

Standard features include grooved tubing and louvered fins. Coil circuiting has also been updated to make the most of all Carrier heat pumps and air conditioners. Units come with solid state fan controls, 1-inch (25mm) thick insulation with R-value of 4.2, multi-speed motors, and fully-wettable coils. Units can accommodate factory- and/or field-installed heaters from 3 to 30 kW. Assembled at the factory compliant with low leak requirements of less than 2% cabinet leakage rate at 0.5 inches W.C. and 1.4% cabinet leakage rate at 0.5 inches W.C. when tested in accordance with ASHRAE 193 standard.

The FJ5 fan coil design is loaded with popular features. These fan coils utilize the latest in electronic commutation motor (ECM) technology through the use of high efficiency, multi-tap ECM motors allowing reliable air delivery with increased static pressure. It comes in a pre-painted (taupe metallic) galvanized steel casing. The unit is shipped with a Puron Advance refrigerant TXV (sizes 18–60).

STANDARD FEATURES
• Refrigerant leak detection dissipation system for added safety
• Multi-tap ECM (electronic commutating motor) motors – all sizes.
• Integrated motor controls, with 90-sec off TDR function, have
replaced integrated circuit board.
• Five available speed tags to meet a wide range of applications.
• Large, grooved tube, louvered fin coils.
• Efficient, quiet, time-tested blower housings and diffusers.
• Sturdy, drainable condensate pans.
• Construction innovations designed to prevent cabinet sweating.
• Tested for condensate disposal in much tougher conditions than Air
Conditioning and Refrigeration Institute requirements.
• Super-thick R-4.2 insulation with vapor barrier.
• Pre-painted galvanized steel cabinet (taupe metallic).
• Design meets stringent regulations for cabinet air leakage of less than
2% when tested at 0.5 inches W.C., and less than 1.4% at 0.5 inches
W.C. when tested in accordance with ASHRAE 193 standard.
• Installation-flexible, multipoise units.
• 2-piece modular design available for 42 thru 60 sizes. Facilitates attic
and crawlspace installations..
• Horizontal hanging provisions on cabinet.
• Newly improved filter rack area filter door insulation added for
improved air seal. No tools required to access filter.
• Factory-installed heater packages available on select models.
(5 through 15 kW).
• 3 through 30 kW accessory heaters - field installed.
• Easy plug-in provisions for heater installation.
• Entry options for high and low voltage wiring hook-up.
• Leak-preventing sweat connections.
• Factory installed thermostatic expansion valve, TXV, on all coils.
• Designed for manufactured housing applications.

WARRANTY
• Default 5-year parts limited warranty:
– 10-year parts limited warranty with timely registration*.
Equipment must be registered within 90 days of original installation, except in jurisdictions where warranty benefits cannot be conditioned on registration.
* Applies to original purchaser/homeowner and not available to subsequent owners, except in jurisdictions where laws dictate otherwise.
See Warranty certificate for complete details and restrictions.

 

More Information
Brand/ Manufacturer Carrier®
Model #26SCA530 FJ5ANXB36L
System TypeCooling Only
Product SeriesComfort™ 15 1Stg R454B
Tons2.5
BTU29400
Nominal SEER15 SEER
System SEER15 SEER
Rated SEER15.5
Rated EER13
RefrigerantR-454B
Install PositionFJ5 Multi-Position R454B
AFUE %N/A
Pad Size36x36x3
Suction Line Size3/4"
Liquid Line Size3/8"
Write Your Own Review
You're reviewing:Carrier® Comfort™ 2.5 Ton 15 SEER2 (Rated 15.5 SEER) 1 Stage AC Only or Electric Heat| R-454B|w/FJ5 VS Air Handler 17.5"W| 26SCA530 FJ5ANXB36L
Ask a question

Submit
Close