KFADC0401ACL Downflow Conversion Kit (A Coil Only)
KFAHD0101SLP Horizontal /Downflow Gasket Kit
To convert units for downflow applications, refer to Installation Instructions supplied with kit for proper installation. For slope fan coils, use kit Part No. KFADC0201SLP. For A--coils, use kit Part No. KFADC0401ACL. Use fireproof resilient gasket, 1/8 to 1/4--in (3 to 6 mm) thick, between duct, unit, and floor. NOTE: Gasket kit number KFAHD0101SLP is also required for all downflow applications to maintain low air leak/low sweat performance. C. Horizontal Installation Units must not be installed with access panels facing up or down. All other units are factory built for horizontal left installation. (See Fig. 2 and 3.) When suspending unit from ceiling, dimples in casing indicate suitable location of screws for mounting metal support straps. (See Fig. 2.) For horizontal applications having high return static and humid return air, the Water Management Kit, KFAHC0125AAA, may need to be used to assist in water management.
Model # | KFADC0401ACL-KFAHD0101SLP |
---|---|
Brand/ Manufacturer | Carrier |
Accessory Type | Install Kits |